Designed to mate naturally with any standard security panels to facilitate "perimeter security" within a total security package. The low current draw, 12 volt power input requirements, and advanced operational algorithm provide a stable addition to all security systems

 

However, even when installed as a "Stand Alone" operational package it is a awesome security instrument, and is especially efficient by keeping intruders out of your property before they can do any damage, and most of the time makes additional security devices redundant.

Battery Powered for 24-7 operation,
even with power failures.
The 30 ma power draw can be easily supplied
directly from a
"standard" security control panel.

WEED ALERT ®:

  • Adjustable Voltage Setting: 1,500 volts to 8,000 volts with a specific separate, and isolated output when the voltage drops past the pre-adjusted voltage level, it will alert the user to inspect and/or clean the fence before the voltage becomes ineffectual and therefore useless. This feature is unique to the Electric Fence monitor/sensor

OPERATIONAL PARAMETERS:

  • Input Power Requirements: 12 to 24 volts DC

  • Power Usage: The input power usage is 0.25 watts

  • High Voltage Input Pulse: 200 volt to 25,000 volt

  • Pulse Width Accepted: 50 microseconds to 10 milliseconds

  • Pulse Period Accepted: 5 hertz to 0.5 hertz (5 pulses/sec to 2 seconds) between pulses

  • Maintenance Output: Contact closure rated 0.5 amps @ 60vdc and 100 vac (This is sufficient for most piezo sounders) Maintenance voltage level is variable from 1.5kv to 8kv input

  • Voltage Loss Output: When pulse voltage is less than 0.2kv  Contact closure rated 0.5 amps @ 60vdc and 100 vac  (most sirens and loud alarms will require a power contactor/relay to provide for sufficient current switching)

  • Automatic Reset: Both the "Weed Alert" and "Alarm" functions automatically reset when voltages are restored. For security purposes, a latching circuit or relay to maintain the alarm is recommended for some applications.

INDICATING LIGHTS (LED's):

  • Green LED flashes for every high voltage pulse that is a higher voltage than the set-point or maintenance required voltage.

  • Yellow/Amber LED indicates that the high voltage pulse has dropped below the "set-point" voltage for a continuous 100 seconds, and your fence requires maintenance. Also the low voltage contacts will close. Clearing the grass and weeds from the fence usually clears this indication unless there is another problem.

  • Red LED indicates that there is a loss of voltage and immediate action should be taken to preserve the integrity of your fence and protect your property and stock.

TERMINAL CONNECTIONS:

  • The relay contacts are voltage isolated which provides versatility and will not interfere with other operational components.

  • terminals 1 & 2 are the "No Voltage" contacts and correspond to the RED indicator

  • terminals 3 & 4 are the "Low Voltage" contacts and correspond to the YELLOW indicator

  • terminals 5 & 6 are the power input has is to be connected to a power source of 12 to 24 volts DC. A 12 volt battery or AC adapter. Generally we advise to install with a 12 volt battery connected to a continuous charging or "smart" battery charger. This will provide protection and monitoring even during utility losses. A fully charged 12 volt- 7amp-hour battery will provide power for the unit in excess of 3 days before requiring recharging.

  • An Installation and operation instruction booklet are included with each sensor

  • A circuit layout is printed on the inside of the sensor cover.

OPERATION:
     This high voltage sensor takes an electric fence charger pulse and analyzes it for peak voltage, pulse width and period. The RG7781 can accurately measure voltage pulses from almost any fence charger or pulse source, including the spark voltage on a gasoline engine.

     The design algorithm used in this device was determined for stability, longevity, and reliability under a wide set of usage parameters. (patents applied and pending )

     The green light will flash for every pulse that is higher than the maintenance voltage. The maintenance threshold voltage is set at 6kv at the factory.

      This maintenance voltage setting is adjustable from 1.5kv to 8kv. If flora (grass, bushes, limbs, and leaves) partially load or partially short out the fence voltage and reduce the effective pulse voltage to below the adjustable maintenance level voltage set point, then the yellow LED will light and the maintenance contacts will close. The maintenance function has an approximate 100 second delay to avoid false alarms. If the grass or limb is blown off or removed and the charger pulse voltage is restored, then the maintenance alarm will reset itself and the maintenance contacts will open.

     When the pulse voltage drops or becomes less than 0.2 kv, the "no voltage" contacts will close. There is a factory set delay of 6 seconds (adjustable to 55 seconds) before the red LED will light and the alarm contact close to eliminate "false alarms". The algorithm used in this circuit also eliminates false alarms  from reverse pulses that may occur from close proximity lightening strikes. If the voltage drop is intermittent the circuit will reset itself. (For some security applications, a latching relay contact  may be desired on some output relays.)

     This device is designed for long life with ease and consistency of operation and all units have a two (2) year warranty including lightening damage.

WARRANTY:
     Each unit is unconditionally guaranteed for a period of two years (24 months) from the date of retail sale. Sales slip shall accompany each returned unit. We reserve the right to either repair or replace the unit at our discretion. Failed units can be returned to the place of purchase or to our receiving office. 